GESCHENKEGIGANT.DE ≡ One-Piece Armour & Weapons Low Vision Magnifiers Bonnie & Camille
  • Maternity

  • Patient Monitor Yonker 12inch Yk-8000B

Patient Monitor Yonker 12inch Yk-8000B

$67.75 $103.66
TECHNICAL SPECIFICATIONS Multiparameter Patient Monitor • CE, ISO13485 • SFDA: Class Ⅱb • Anti-electroshock degree:ClassⅠ equipment (internal power supply) • TEMP/SpO 2 /NIBP: BF • ECG/Resp: CF Quality Standards and Classification • Adult/Pediatric/Neonatal(Necllor Spo2&Suntch Nibp)/Surgery/ Operating Room/ICU/CCU (Seperated parameter board) Application Range • 12.1”TFT screen Display Operating environment : • Temperature: 0 ~ 40 ℃ • Humidity: 15% ~ 80% • Pressure: 86.0 kPa ~ 106.0kPa Transport and Storage environment : • Temperature: -20 ~ 55 ℃ • Humidity: 10% ~ 90% • Pressure: 86.0 kPa ~ 106.0kPa Environment • AC: 100 ~ 240V, 50Hz/60Hz • DC: Built-in rechargeable battery • Battery: 11.1V 24wh Li-ion battery • 2h operating after full charge • 5min operating after low battery alarm Power Requirements • Equipment : 305*162*290mm(about) ; 4kg(about) • Package : 380*350*300mm(about) ; 6kg(about) Dimension and Weight • Trend diagram/table: 720h • NIBP review: 10000 events • Wave review: 12h • Alarm review: 200 alarm events • Support drug concentration titration analysis Date Storage • 5 Leads: RA, LA, LL, RL, V • Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V ECG • Gain: × 1.25mm/mV,2.5mm/mV, • 5.0mm/mV, 10mm/mV, • 20mm/mV (error 5%) • Sweep speed: 6.25mm/s,12.5mm/s,25mm/s, • 50mm/s (error≤ ±10%) • Bandwidth: Surgery 1 ~ 25 Hz • Monitor 0.5 ~ 40 Hz • Diagnostic 0.05 ~ 130 Hz • Sensitivity: >200 V P-P • CMRR≥ 112dB • Differential Input Impedance: >5M • ohm Electrode Offset Potential ±300mV • Polarization Voltage ≥±500mV • Input Impedance ≥5 M • Calibration Voltage: 1mV± 5% Max. Mean Error 5mmHg Max. Standard Deviation: 8mmHg • Overpressure protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg • ST Segment Range: -2.0mV ~ 2.0mV • Accuracy: Ranging -0.8 mV ~ 0.8mV, measuring error is ±0.02mV or ±10%, The larger prevails. No definition for other ranges. ST Segment • Method: impedance between RA-LL • Resp Impedance range: 0.3 ~ 3 • Base Impedance range: 200 ~ 4000 • Bandwidth: 0.3 ~ 2.5Hz • Gain: × 0.25, × 0.5, × 1, × 2, × 4 • Resp rate:Measurement Range Adult 0 ~ 120BrPM Neonatal/Pediatric 0 ~ 150BrPM • Resolution: 1BrPM • Accuracy: 7 ~ 150BrPM ( 2BrPM) 0 ~ 6BrPM (unspecified) • Apnea Alarm: 10 ~ 40s RESP • Channel 2 • Measure & alarm range: 0 ~ 50 ℃ • Resolution: 0.1 ℃ • Accuracy (no sensor) ±0.1 ℃ (0~50 ℃) (excluding sensor error)TEMP • ECG cable & electrodes • SpO2 sensor • TEMP probe • NIBP cuff & tube • Power cord • Lithium-ion battery • User manual Standard accessories • Etco2 (Optional) • Dual IBP (Optional) • Nellcor Spo2 (Optional) • Suntch Nibp (Optional) • Recorder (Optional) Optional •Measurement range: 0 ~ 100% •Resolution: 1% •Precision: 70% ~ 100% ±2% 0%~69%:no definition given SpO2 •Measure/alarm range: 20 ~ 300bpm •Resolution: 1bpm • Accuracy ±3bpm Pulse Rate •Method: Oscillometry •Measure mode: Manual, Auto, STAT •Measure interval in auto mode:1~5/10/15/30/60/90/120/ 180/240/480min •Measure period in STAT mode: 5min •Pulse rate range: 40 ~ 240bpm •Measure & alarm range: Adult SYS 40 ~ 280mmHg DIA 10 ~ 220mmHg MEAN 20 ~ 240mmHg Pediatric SYS 40 ~ 220mmHg DIA 10 ~ 160mmHg MEAN 20 ~ 170mmHg Neonatal SYS 40 ~ 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg • Static pressure measurement Range: 0 ~ 300mmHg Accuracy 3mmHg Resolution: 1mmHg Accuracy:
Maternity

Maternity

  • Gynaecological Examination Bed
    $50.54 $74.29
  • CONTEC PULSE OXIMETER
    $48.51 $68.88
  • Fetal Doppler – Rechargeable
    $36.62 $52.37
  • Patient Monitor Yonker 12inch Yk-8000B
    $67.75 $103.66
  • Infusion Pump SP750
    $69.35 $130.38
  • Child cot bed ( Single crank)
    $36.24 $66.68
  • Examination Bed - Foldable
    $38.26 $52.8
  • Shower Chair with backrest and armrest
    $67.82 $114.62
  • ABS Baby Carriage
    $36.63 $49.08

© 2026 - GESCHENKEGIGANT.DE